🎉 Up to 70% Off Selected ItemsShop Sale
DIN Rail Mounting 12V DC Power Supply - 100–240VAC, 0.5A In - 12VDC, 1.25A Out, UL, 50/60Hz
HomeStore

DIN Rail Mounting 12V DC Power Supply - 100–240VAC, 0.5A In - 12VDC, 1.25A Out, UL, 50/60Hz

DIN Rail Mounting 12V DC Power Supply - 100–240VAC, 0.5A In - 12VDC, 1.25A Out, UL, 50/60Hz

$10.50

Original: $30.00

-65%
DIN Rail Mounting 12V DC Power Supply - 100–240VAC, 0.5A In - 12VDC, 1.25A Out, UL, 50/60Hz

$30.00

$10.50

The Story

This is a 12V DC Power Supply - DIN Rail Mounting - 100–240VAC, 0.5A In - 12VDC, 1.25A Out, UL Listed, CE, 50/60Hz ~section 2~

Type: 12V DC Power Supply

Input: 100-240 volts ~ 50/60Hz

Output: 12 Volts – 1.25A

Certifications: CEUL and cUL Listed, RoHS, Double Insulated

Usage: Use Indoors or in a Watertight Enclosure

We're now providing these power supplies for our metering customers only. They are ideally suited for use with the 485Bee radios or the EKM Push gateway, when a standard wall outlet is not available. This power supply can be mounted alongside our electric meters on the same piece of TS35 Standard (35mm) DIN rail, which is included with all of the Enclosures we offer.

Please, note: DIN rail is not included with this power supply.

Installation:

 

1.) Always allow for good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit, to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.

2.) Mount vertically with the input terminals at the bottom.

3.) Use with copper wire only. Use 14–18 AWG on the input side, 14-24 AWG on the output side (CAT5 twisted pair wire works well in our experience).

4.)  Ports N (Neutral) and L (Hot Line) are the 120-240 volt AC inputs.  Ports +V and the -V are the DC outputs.

5.) Remove 6mm of insulation from the ends of the wires.

6.) Use a 3mm slotted screwdriver for the terminals. 

7.) The power supply clips onto the DIN rail by clipping the top of the DIN rail receiver, on the power supply, over the top of the DIN rail first. Then the power supply is rotated down so that the clip at the bottom of the power supply can engage with the DIN rail. You should hear a click when it engages. If you don't you might need to pull down on the clip and then push the power supply towards the DIN rail. Then release the clip so that it engages with the DIN rail. You will know it is engaged if you try to move the power supply and it remains clipped to the DIN rail.

8.) If you are using the DIN Rail power supply to power the Push3 gateway:  hardwire connect V+ on the DIN Rail Power Supply to the +12VDC input of the EKM Push (pos is the left port of the 2-port terminal block) and hardwire connect V- on the DIN Rail Power Supply to the -12VDC input of the EKM Push (neg is the right port of the 2-port terminal block).

For more information about our products and services, we encourage you to visit our online Knowledge Base, which provides spec sheets, videos, tutorials, FAQs, diagrams, and more.

Spec Sheet: 12V DIN Rail Mountable Power Supply spec sheet


DIN Rail Mounting 12V DC Power Supply - 100–240VAC, 0.5A In - 12VDC, 1.25A Out, UL, 50/60Hz - Image 2

Details & Craftsmanship

Every detail has been carefully considered to bring you the perfect product.

Description

This is a 12V DC Power Supply - DIN Rail Mounting - 100–240VAC, 0.5A In - 12VDC, 1.25A Out, UL Listed, CE, 50/60Hz ~section 2~

Type: 12V DC Power Supply

Input: 100-240 volts ~ 50/60Hz

Output: 12 Volts – 1.25A

Certifications: CEUL and cUL Listed, RoHS, Double Insulated

Usage: Use Indoors or in a Watertight Enclosure

We're now providing these power supplies for our metering customers only. They are ideally suited for use with the 485Bee radios or the EKM Push gateway, when a standard wall outlet is not available. This power supply can be mounted alongside our electric meters on the same piece of TS35 Standard (35mm) DIN rail, which is included with all of the Enclosures we offer.

Please, note: DIN rail is not included with this power supply.

Installation:

 

1.) Always allow for good ventilation clearances, 5mm left and right, 40mm above and 20mm below, around the unit, to prevent it from overheating. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.

2.) Mount vertically with the input terminals at the bottom.

3.) Use with copper wire only. Use 14–18 AWG on the input side, 14-24 AWG on the output side (CAT5 twisted pair wire works well in our experience).

4.)  Ports N (Neutral) and L (Hot Line) are the 120-240 volt AC inputs.  Ports +V and the -V are the DC outputs.

5.) Remove 6mm of insulation from the ends of the wires.

6.) Use a 3mm slotted screwdriver for the terminals. 

7.) The power supply clips onto the DIN rail by clipping the top of the DIN rail receiver, on the power supply, over the top of the DIN rail first. Then the power supply is rotated down so that the clip at the bottom of the power supply can engage with the DIN rail. You should hear a click when it engages. If you don't you might need to pull down on the clip and then push the power supply towards the DIN rail. Then release the clip so that it engages with the DIN rail. You will know it is engaged if you try to move the power supply and it remains clipped to the DIN rail.

8.) If you are using the DIN Rail power supply to power the Push3 gateway:  hardwire connect V+ on the DIN Rail Power Supply to the +12VDC input of the EKM Push (pos is the left port of the 2-port terminal block) and hardwire connect V- on the DIN Rail Power Supply to the -12VDC input of the EKM Push (neg is the right port of the 2-port terminal block).

For more information about our products and services, we encourage you to visit our online Knowledge Base, which provides spec sheets, videos, tutorials, FAQs, diagrams, and more.

Spec Sheet: 12V DIN Rail Mountable Power Supply spec sheet


You may also like

-65%NEW
Thumbnail 1Thumbnail 2

EKM Inline Fuse Holder With 1 Amp Fuse

$7.00

$2.45

-65%NEW
Thumbnail 1Thumbnail 2

Dielectric Grease - RS-485 and Pulse Output, Wire Connection Weather Proofing

$1.00

$0.35

-65%NEW
Thumbnail 1Thumbnail 2

12V DC Power Supply - 1000mA, UL & cUL Listed, 60Hz

$10.00

$3.50

NEW
Thumbnail 1Thumbnail 2

Sticker Label Sheet

$4.00

-65%NEW
Thumbnail 1Thumbnail 2

3 Ft. Ethernet Cable

$6.00

$2.10

-65%NEW
Thumbnail 1Thumbnail 2

8 Digit Pulse Counter v.2

$70.00

$24.50

-65%NEW
Thumbnail 1Thumbnail 2

EKM Insulation Piercing Connector

$10.00

$3.50

-65%NEW
Thumbnail 1Thumbnail 2

4-Twisted Pairs of Wire, CAT5e RS-485 Shielded, Stranded PVC Cable (FTP), 50 feet

$35.00

$12.25

-65%NEW
Thumbnail 1

EKM Lever Nut

$1.50

$0.52

-65%NEW
Thumbnail 1Thumbnail 2

EKM Tamper-Proof Meter Seal

$1.50

$0.52

-65%NEW
Thumbnail 1Thumbnail 2

12V Power Supply Splitter - 2.1x5.5mm

$5.00

$1.75